MultiEval

SCPI Commands :

TRIGger:NRSub:MEASurement<Instance>:MEValuation:SOURce
TRIGger:NRSub:MEASurement<Instance>:MEValuation:THReshold
TRIGger:NRSub:MEASurement<Instance>:MEValuation:SLOPe
TRIGger:NRSub:MEASurement<Instance>:MEValuation:DELay
TRIGger:NRSub:MEASurement<Instance>:MEValuation:TOUT
TRIGger:NRSub:MEASurement<Instance>:MEValuation:MGAP
TRIGger:NRSub:MEASurement<Instance>:MEValuation:SMODe
TRIGger:NRSub:MEASurement<Instance>:MEValuation:FSYNc
class MultiEvalCls[source]

MultiEval commands group definition. 9 total commands, 1 Subgroups, 8 group commands

get_delay() float[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:DELay
value: float = driver.trigger.nrSubMeas.multiEval.get_delay()

Defines a time delaying the start of the measurement relative to the trigger event. This setting has no influence on free run measurements.

return:

delay: numeric Unit: s

get_fsync() bool[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:FSYNc
value: bool = driver.trigger.nrSubMeas.multiEval.get_fsync()

Enables frame synchronization for ‘Free Run (Fast Sync) ‘ and ‘IF Power’.

return:

frame_sync: OFF | ON OFF: slot synchronization ON: frame synchronization

get_mgap() float[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:MGAP
value: float = driver.trigger.nrSubMeas.multiEval.get_mgap()

Sets a minimum time during which the IF signal must be below the trigger threshold before the trigger is armed so that an IF power trigger event can be generated.

return:

min_trig_gap: numeric Range: 0 s to 1E-3 s, Unit: s

get_slope() SignalSlope[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:SLOPe
value: enums.SignalSlope = driver.trigger.nrSubMeas.multiEval.get_slope()

Qualifies whether the trigger event is generated at the rising or at the falling edge of the trigger pulse (valid for external and power trigger sources) .

return:

slope: REDGe | FEDGe REDGe: Rising edge FEDGe: Falling edge

get_smode() SyncMode[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:SMODe
value: enums.SyncMode = driver.trigger.nrSubMeas.multiEval.get_smode()

Selects the size of the search window for synchronization.

return:

sync_mode: NORMal | ENHanced | NSSLot | ESSLot Normal, enhanced, normal single slot, enhanced single slot

get_source() str[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:SOURce
value: str = driver.trigger.nrSubMeas.multiEval.get_source()

Selects the source of the trigger events. Some values are always available. They are listed below. Depending on the installed options, additional values are available. You can query a list of all supported values via TRIGger:… :CATalog:SOURce?.

return:

source: string ‘Free Run (Fast Sync) ‘ Free run with synchronization ‘Free Run (No Sync) ‘ Free run without synchronization ‘IF Power’ Power trigger (received RF power)

get_threshold() float[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:THReshold
value: float or bool = driver.trigger.nrSubMeas.multiEval.get_threshold()

Defines the trigger threshold for power trigger sources.

return:

trig_threshold: (float or boolean) numeric Range: -50 dB to 0 dB, Unit: dB (full scale, i.e. relative to reference level minus external attenuation)

get_timeout() float[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:TOUT
value: float or bool = driver.trigger.nrSubMeas.multiEval.get_timeout()

Selects the maximum time that the measurement waits for a trigger event before it stops in remote control mode or indicates a trigger timeout in manual operation mode. This setting has no influence on ‘Free Run’ measurements.

return:

trigger_timeout: (float or boolean) numeric | ON | OFF Range: 0.01 s to 167772.15 s, Unit: s ON | OFF enables or disables the timeout check.

set_delay(delay: float) None[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:DELay
driver.trigger.nrSubMeas.multiEval.set_delay(delay = 1.0)

Defines a time delaying the start of the measurement relative to the trigger event. This setting has no influence on free run measurements.

param delay:

numeric Unit: s

set_fsync(frame_sync: bool) None[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:FSYNc
driver.trigger.nrSubMeas.multiEval.set_fsync(frame_sync = False)

Enables frame synchronization for ‘Free Run (Fast Sync) ‘ and ‘IF Power’.

param frame_sync:

OFF | ON OFF: slot synchronization ON: frame synchronization

set_mgap(min_trig_gap: float) None[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:MGAP
driver.trigger.nrSubMeas.multiEval.set_mgap(min_trig_gap = 1.0)

Sets a minimum time during which the IF signal must be below the trigger threshold before the trigger is armed so that an IF power trigger event can be generated.

param min_trig_gap:

numeric Range: 0 s to 1E-3 s, Unit: s

set_slope(slope: SignalSlope) None[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:SLOPe
driver.trigger.nrSubMeas.multiEval.set_slope(slope = enums.SignalSlope.FEDGe)

Qualifies whether the trigger event is generated at the rising or at the falling edge of the trigger pulse (valid for external and power trigger sources) .

param slope:

REDGe | FEDGe REDGe: Rising edge FEDGe: Falling edge

set_smode(sync_mode: SyncMode) None[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:SMODe
driver.trigger.nrSubMeas.multiEval.set_smode(sync_mode = enums.SyncMode.ENHanced)

Selects the size of the search window for synchronization.

param sync_mode:

NORMal | ENHanced | NSSLot | ESSLot Normal, enhanced, normal single slot, enhanced single slot

set_source(source: str) None[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:SOURce
driver.trigger.nrSubMeas.multiEval.set_source(source = 'abc')

Selects the source of the trigger events. Some values are always available. They are listed below. Depending on the installed options, additional values are available. You can query a list of all supported values via TRIGger:… :CATalog:SOURce?.

param source:

string ‘Free Run (Fast Sync) ‘ Free run with synchronization ‘Free Run (No Sync) ‘ Free run without synchronization ‘IF Power’ Power trigger (received RF power)

set_threshold(trig_threshold: float) None[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:THReshold
driver.trigger.nrSubMeas.multiEval.set_threshold(trig_threshold = 1.0)

Defines the trigger threshold for power trigger sources.

param trig_threshold:

(float or boolean) numeric Range: -50 dB to 0 dB, Unit: dB (full scale, i.e. relative to reference level minus external attenuation)

set_timeout(trigger_timeout: float) None[source]
# SCPI: TRIGger:NRSub:MEASurement<Instance>:MEValuation:TOUT
driver.trigger.nrSubMeas.multiEval.set_timeout(trigger_timeout = 1.0)

Selects the maximum time that the measurement waits for a trigger event before it stops in remote control mode or indicates a trigger timeout in manual operation mode. This setting has no influence on ‘Free Run’ measurements.

param trigger_timeout:

(float or boolean) numeric | ON | OFF Range: 0.01 s to 167772.15 s, Unit: s ON | OFF enables or disables the timeout check.

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.trigger.nrSubMeas.multiEval.clone()

Subgroups